Skip to content
// SYSTEMS — POWER
09Deployable todaySegal Stagecraft

Power & Distribution

Nothing on this list runs without clean, redundant power. We design the grid before we hang a fixture.

TC MASTERGENSETPARALLELDISTROUPSA-FEEDB-FEEDREDUNDANT BACKUP — AUTO-FAILOVERPRIMARY — FRAME-LOCKED
The grid designed before the first fixture hangs — A/B power and UPS on everything show-critical.One-line
// WHAT WE OWN

We design the grid first — generation, distribution, and redundancy — to a load calc and a one-line diagram per venue. Show-critical racks get A/B power and UPS, so the spine never browns out mid-cue.

// INVENTORY — FIXTURE CLASSES

Reference-grade, not a fixed rental list.

Generation

  • Quiet / whisper gensets
  • Paralleling
  • Shore-power tie-in

Distribution

  • Distro racks
  • Cam-lock + socapex runs
  • Isolation / grounding
  • Phase balancing

Redundancy

  • UPS on control + critical systems
  • A/B power for show-critical racks
  • Load calc per venue
// COMPONENTS — SPECS

3 component classes. Expand for the spec sheet.

GenerationQuiet gensets, paralleled, with shore tie-in.

Quiet/whisper gensets, paralleled for capacity and redundancy, with shore-power tie-in — sized to a load calc per venue before anything hangs.

  • Whisper genset
  • Paralleling
  • Shore-power
GenerationQuiet / whisper diesel gensets
CapacityParalleled, load-calc sized
Tie-inShore-power transfer
DocsLoad calc per venue
DistributionDistro racks, cam-lock and socapex runs.

Distribution racks with cam-lock and socapex runs, isolation and grounding, and phase balancing — a documented one-line diagram for every build.

  • Cam-lock / socapex
  • Isolation
  • One-line
DistroRacks, cam-lock + socapex runs
GroundingIsolation, bonding, phase balance
MonitoringMetered, fault isolation
DocsOne-line diagram per build
UPS & RedundancyA/B power and UPS on everything show-critical.

UPS on control and critical systems, with A/B power to show-critical racks so the spine never browns out mid-cue.

  • UPS
  • A/B power
  • Show-critical
UPSOn control + critical systems
RedundancyA/B feeds to show-critical racks
CoverageNetwork, servers, consoles
FailoverSeamless transfer
// CONTROL LAYER

What makes it frame-accurate.

  • Monitored distribution; fault isolation.
  • Documented one-line diagram per build.
  • Load calc verified before the first fixture hangs.
// THE PIPELINE
01CONCEIVE
02DESIGN
03ENGINEER
04STAGE
05PERFORM
// HONEST STATUS
Deployable today

Spec'd, owned, ready to rig.

Spec a power package, built and run by the crew that designed it.

Spec a power package →